{"product_id":"tuttnauer-tvet-9m","title":"Tuttnauer TVET 9M Manual Veterinary Autoclave","description":"\u003ch5\u003eDescription \u0026amp; Specifications\u003c\/h5\u003e\u003cp\u003eManual veterinary autoclave\u003c\/p\u003e\u003cp\u003eTVET 9M\u003c\/p\u003e\u003cp\u003eThe most cost-efficient solution for your clinic.\u003c\/p\u003e\u003cp\u003eThe perfect Autoclave developed exclusively for Veterinarians. The tvet line fits all your sterilization needs by creating cycle parameters to accommodate double wrapped pouches. These cycles ensure sterility and efficient drying of packs and pouches, helping veterinarians meet today's challenging workloads.\u003c\/p\u003e\u003cp\u003eA small and affordable veterinary autoclave, built to last\u003c\/p\u003e\u003cp\u003eThe small but mighty tvet 9M offers unparalleled quality for clinics on a budget. This maintenance free plug-and-play autoclave features a 5-gallon stainless steel chamber, just big enough to fit your most important veterinary equipment. Activate each stage of the sterilization cycle with a single touch. Packed with features for the fastest, most versatile operation, the tvet 9M delivers outstanding performance , unmatched safety features and intuitive controls for the most demanding high volume environments.\u003c\/p\u003e\u003cp\u003e3 Trays. Tray handle included\u003c\/p\u003e\u003cp\u003eSafe-Locking Door\u003c\/p\u003e\u003cp\u003eEasy to use with one hand, the decorative stainless steel door has a double safety mechanism\u003c\/p\u003e\u003cp\u003eIntuitive Control\u003c\/p\u003e\u003cp\u003eDesigned with the operator in mind, the colorful control panel is intuitive and easy to use\u003c\/p\u003e\u003cp\u003eSimple Drainage\u003c\/p\u003e\u003cp\u003eA drainage valve is conveniently located at the front, allowing you to quickly and easily drain the water reservoir\u003c\/p\u003e\u003cp\u003eDurable Chamber\u003c\/p\u003e\u003cp\u003eMade to last, the electropolished 316L stainless steel chamber is backed by a 10-year warranty\u003c\/p\u003e\u003cp\u003eOverheating Protection\u003c\/p\u003e\u003cp\u003eThe dual safety thermostat and automatic shut-off at the end of all cycles provide reliable overheating protection\u003c\/p\u003e\u003cp\u003eTechnical specifications\u003c\/p\u003e\u003cp\u003eDimensions  (D x W x H)*\u003c\/p\u003e\u003cp\u003e21.5” x 20.1” x 14.4”\u003c\/p\u003e\u003cp\u003e545mm x 510mm x 365mm\u003c\/p\u003e\u003cp\u003eChamber Dimensions\u003c\/p\u003e\u003cp\u003e9” x 18”\u003c\/p\u003e\u003cp\u003e230mm x 470mm\u003c\/p\u003e\u003cp\u003eChamber Volume\u003c\/p\u003e\u003cp\u003e19 Liter\u003c\/p\u003e\u003cp\u003e5 Gallon\u003c\/p\u003e\u003cp\u003eTray Capacity\u003c\/p\u003e\u003cp\u003e3 Trays\u003c\/p\u003e\u003cp\u003eTray Dimensions\u003c\/p\u003e\u003cp\u003e16,3” x 6,7\" x 0.8”,\u003c\/p\u003e\u003cp\u003e442mm x 170mm x 20mm\u003c\/p\u003e\u003cp\u003eStandard Cassette Capacity\u003c\/p\u003e\u003cp\u003e2 Full, 2 Half *\u003c\/p\u003e\u003cp\u003eVoltage \u0026amp; Frequency\u003c\/p\u003e\u003cp\u003e120V\u003c\/p\u003e\u003cp\u003e50-60Hz\u003c\/p\u003e\u003cp\u003ePower \u0026amp; Current\u003c\/p\u003e\u003cp\u003e1400W\u003c\/p\u003e\u003cp\u003e12A\u003c\/p\u003e\u003cp\u003eShipping Weight\u003c\/p\u003e\u003cp\u003e85 Lbs\u003c\/p\u003e\u003cp\u003e39 kg\u003c\/p\u003e\u003cp\u003eNOTE\u003c\/p\u003e\u003cp\u003e* Standard full size cassette is 8” x 11” and standard half size cassette is 8” x 5.5”\u003c\/p\u003e\u003cp\u003eStandards \u0026amp; Directives\u003c\/p\u003e\u003cp\u003ePressure Vessel\u003c\/p\u003e\u003cp\u003eAll pressure vessels and boilers are certified according to ASME code section I and section VIII, Div. I and 2014\/68\/EU – Pressure Equipment Directive\u003c\/p\u003e\u003cp\u003eQuality Standards\u003c\/p\u003e\u003cp\u003eISO 9001:2015 Quality Management System\u003c\/p\u003e\u003cp\u003eISO 13485:2016 Quality Management System – Medical Devices\u003c\/p\u003e\u003cp\u003eISO 14001:2015 Environmental Management System\u003c\/p\u003e\u003cp\u003eCanadian MDR (CMDR) SOR\/98-282 (2018), consolidated\u003c\/p\u003e\u003cp\u003eTechnical Standards\u003c\/p\u003e\u003cp\u003eANSI\/AAMI ST55:2016\u003c\/p\u003e\u003cp\u003eDirectives\u003c\/p\u003e\u003cp\u003e93\/42\/EEC Medical Devices Directive\u003c\/p\u003e\u003cp\u003e2006\/42\/EC Machinery Directive\u003c\/p\u003e\u003cp\u003e2014\/35\/EU Low Voltage Directive\u003c\/p\u003e\u003cp\u003e2014\/30\/EU Electromagnetic Compatibility Directive\u003c\/p\u003e\u003cp\u003e2012\/19\/EU WEEE and 2011\/65\/EU RoHS\u003c\/p\u003e\u003cp\u003eEN 61010-2-040\u003c\/p\u003e\u003cp\u003eEN 554 EN 61326 EN 61326\u003c\/p\u003e\u003cp\u003eComplying with MDD 93\/42, PED 97\/23, RoHS \u0026amp; WEEE Directives(IP31)\u003c\/p\u003e\u003cp\u003eNeed more Information?\u003c\/p\u003e\u003cp\u003eBrochure\u003c\/p\u003e\u003cp\u003eDownload the brochure and learn more about this autoclaves capabilities\u003c\/p\u003e\u003cp\u003eNeed help choosing?\u003c\/p\u003e\u003cp\u003eReady to place your order? We are here to assist you with any questions you may have.\u003c\/p\u003e\u003cp\u003eGet in touch\u003c\/p\u003e\u003ch5\u003eResources\u003c\/h5\u003e\u003cp\u003e\u003ca href=\"https:\/\/tuttnauer.com\/us\/veterinary-practices\/tabletop-sterilizers\/manual\/tvet-9m\" target=\"_blank\"\u003eManufacturer product information\u003c\/a\u003e\u003c\/p\u003e","brand":"Manufacturer: Tuttnauer","offers":[{"title":"TVET 9M","offer_id":67805790666978,"sku":"TVET 9M","price":5271.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/5845\/files\/tvet10m_png.webp?v=1792879405","url":"https:\/\/www.dentamedusa.com\/products\/tuttnauer-tvet-9m","provider":"dentamedusa.com","version":"1.0","type":"link"}