Skip to content

Vector Vortex Extra Oral External Evacuation Unit 110v/60hz

Original price $2,783.00 - Original price $2,783.00
Original price $2,783.00
$3,256.11
$3,256.11 - $3,256.11
Current price $3,256.11
Availability:
In stock

Free returns on all eligible orders

You have 30 days to request a return. All sale items are final sale.

Shipping information

Free Shipping USA on The Most Products USA Only.

Returns & warranty

Return and Refund Policy

Return & Refund Policy

Return Policy (New Products)

Products may be returned within fourteen (14) days of delivery only if they are new, unused, and in original condition.

• All returns require prior authorization from Dentamed USA.
• A Return Authorization (RA) number must be issued before any product is returned.
• Returned items must be shipped prepaid by the customer.
• A 30% restocking fee applies to all approved returns.
• Original outbound and return shipping costs are non-refundable.
• Products must be returned in original packaging with all accessories and documentation.

Once the product is received and inspected, the refund amount (item price minus restocking fee) will be issued if the product is confirmed to be new and unused.

Special Orders & Custom Products

Special order items, custom-made products, and made-to-order equipment are not eligible for return, refund, or cancellation.

Cancelled Orders

Orders cancelled after shipment are subject to the standard return policy.
Customers must accept delivery, obtain a Return Authorization number, and return the product to the designated address.
If delivery is refused, return shipping costs and a 30% restocking fee will be deducted from the issued credit.

Refurbished Equipment

All refurbished equipment is inspected and tested prior to shipment.

• Refurbished equipment sales are final.
• Refurbished items are not eligible for return or refund.
• Warranty coverage is specified on the product listing or invoice.

Customers are responsible for verifying delivery access, including door clearance, elevators, ramps, and site conditions prior to placing an order.

Refund Processing

Once an approved return is received and inspected, customers will be notified by email.
Approved refunds will be issued to the original payment method within five (5) to fourteen (14) business days.

If you receive a product that is damaged in transit, defective upon arrival, or shipped in error, please contact Dentamed USA within 48 hours of delivery. We will work with you to resolve the issue through replacement, repair, or another appropriate solution.

Contact Information

Dentamed USA Your Medical Dental Equipment Corp
7950 NW 53rd Street, Suite 337
Doral, FL 33166
United States

Phone: +1 (786) 616-1533
Email: sales@dentamedusa.comEmail: sales@dentamedusa.com  
Phone: +1 (786) 616-1533

Vector Vortex Extra Oral External Evacuation Unit 110v/60hz

The Vector Vortex Extra-Oral suction device uses high volume Extra-Oral suction to capture, contain, clean, sterilize and kill dental aerosols, creating a safer environment for Dentist, Hygienist, Staff and patients.

Features
  • FUNCTIONAL
  • Strong suction pump, large flow, high vacuum, long performance life.
  • EFFICIENT
  • Excellent heat dissipation performance, can work continuously for more than 4 hours.
  • ADJUSTABLE
  • Negative pressure could be regulated according to the clinical need by stepless adjusting knob.
  • ERGONOMIC
  • Ergonomic design does not get in your way while still providing effective removal of droplets.
  • QUIET
  • Low noise, noise level hardly increases when working with ultrasonic scalar, handpiece etc.
  • The Problem of Aerosols and Droplets in Dental Clinics

Most dental treatments requirer the use of instruments such as high and low speed handpieces, ultrasonic scalers, polishers and so on.

  • During the implementation of these instruments, the combination of compressed air and water can vaporize virus and bacteria particles in the patients oral cavity.
  • Highspeed dental handpieces and ultrasonic instruments are particularly problematic because of their speed (400.000 rpm or 30 K etc.) and use of water for coolant and lavage.
  • These atomized micro-droplets can drift a range of 1-2 meters around dental chair.
  • These particles can also be inhaled by the dental professional, staff and other patients.

Reduce the danger of particle/droplet spread!

  • Aerosols are created during oral treatment.
  • Aerosols suspended in the air for an extended time until they settle on surfaces, clothing and equipment or are inhaled into the human
    respiratory tract.
  • Inhaled aerosolized virus and bacteria have
    strong penetrating power and are considered to be the most potentially dangerous particles for transmitting diseases in the lungs.

 

Vector Vortex Extra Oral External Evacuation Unit 110v/60hz

During treatment, doctors and staff using ultrasonic scalers, 3- way syringe, high and low speed handpieces – generate a large amount of water and mist which combined with bacteria such as saliva, blood and other tissue in the patient’s mouth, producing aerosols. The extra-oral suction of the Vector Vortex removes these aerosols to prevent cross-infection between the doctors and the patients. Providing a clear, dry and clean envioronment.

I Have An HVE: Is it Good Enough?

Intra-oral suction can not significantly reduce droplet dispersion! (particulate matter greater than 0.5)

Vector Vortex Extra Oral External Evacuation Unit 110v/60hz

Dispersion rate=Droplets which are not caught/ Total tracked particles number

  • When using intra-oral suction only, 50% ~ 60% of droplets are flying into the air
  • Using intra-oral and extra-oral suction at the same time, the Vector Vortex captures close to 95% of droplet particles.

Vector Vortex Extra Oral External Evacuation Unit 110v/60hz

Capture rate=Total absorbed particles number /Total tracked particles number

In terms of the “capture rate” of droplet particles. The capture rate of the intra-oral and extra-oral suction combination is 40%~70% higher than that of using intra-oral suction only.

Vector Vortex Extra Oral External Evacuation Unit 110v/60hz

How it works

Suction

With strong suction vacuum pressure and high air suction flow rate, the aerosol droplets between the doctor and staff and the patients is sucked into the machine through the adjustable positioning arm, and discharged after thorough purification.

Disinfection

The aerosol entering the machine is filtered through HEPA filter and then sterilized by ultraviolet rays. The air is then discharged after a high charged plasma sterilization and purification.

4 stages of disinfection ensure clean air!

Vector Vortex Extra Oral External Evacuation Unit 110v/60hz

The built-in high-power blower produces 3M/s wind speed creating a negative air space around the oral cavity, removing dental aerosols and droplets. 4 stage disinfection cleans the air from over 99.97% of vapor, dust, bacteria and viruses. First stage primary filter removes large particles and dust. UV filter exposes viruses and bacteria to UV light breaking down the cellular structure. Plasma generator produces +/- ions charging the particles to make the final stage HEPA filter more effective. Final stage HEPA filter captures the remaining vapor, dust bacteria and viruses.

Advantages and Features

  • Strong suction pump, large flow, high vacuum, long performance life.
  • Excellent heat dissipation performance, can work continuously for more than 4 hours.
  • Negative pressure could be regulated according to the clinical need by stepless adjusting knob.
  • Ergonomic design does not get in you way while still providing effective removal of droplets.
  • Low noise, noise level hardly increases when work with ultrasonic scaler, handpiece etc
Details

Install the free arm and connect the power.

Operation procedure

  1. Move the machine to appropriate location engage the brake at the bottom of wheel.
  2. Plug in the power cord and switch on the power.
  3. Pull the free arm to an appropriate position, adjust the pressure/flow with the knob on the control panel.
  4. After use, turn off the power switch, pull back the free arm.
Specifications
  • Voltage:AC110V 60Hz Power:1200VA
  • Noise:≤65 dB
  • Pumping rate:≥3m3/Min
  • Max Vaccum:-20kpa
  • Amount of negative ions:≥100 million/m3
  • Amount of positive ions:≥80 million/m3
  • HEPA Grade:H13 ≥99.97 0.3μm
  • Dimension:320*320*840mm
  • Net weight:36kg
  • Accessories:
    • HEPA Filter (VV-101)
    • Filter A (VV-102)
    • Filter B (VV-103)
    • UV Lamp (VV-108)
    • Halo Shield (VV-105) Replacement Motor (VV-118)
Brochure

Brochure

Related categories

Warehouse Sale

Our most anticipated sale of discontinued items has finally arrived! While supplies last.

Open Box Deal

Their return, your reward! Starting today, shop new exclusive products for less.

Free Shipping

When you spend $50 or more

Here to Help

Get in touch with us 7 days a week

Store Pickup

Pick up your order yourself, for free

Easy Exchanges

Return or exchange within 60 days

Collection list

View All
Description

Vector Vortex Extra Oral External Evacuation Unit 110v/60hz

The Vector Vortex Extra-Oral suction device uses high volume Extra-Oral suction to capture, contain, clean, sterilize and kill dental aerosols, creating a safer environment for Dentist, Hygienist, Staff and patients.

Features
  • FUNCTIONAL
  • Strong suction pump, large flow, high vacuum, long performance life.
  • EFFICIENT
  • Excellent heat dissipation performance, can work continuously for more than 4 hours.
  • ADJUSTABLE
  • Negative pressure could be regulated according to the clinical need by stepless adjusting knob.
  • ERGONOMIC
  • Ergonomic design does not get in your way while still providing effective removal of droplets.
  • QUIET
  • Low noise, noise level hardly increases when working with ultrasonic scalar, handpiece etc.
  • The Problem of Aerosols and Droplets in Dental Clinics

Most dental treatments requirer the use of instruments such as high and low speed handpieces, ultrasonic scalers, polishers and so on.

  • During the implementation of these instruments, the combination of compressed air and water can vaporize virus and bacteria particles in the patients oral cavity.
  • Highspeed dental handpieces and ultrasonic instruments are particularly problematic because of their speed (400.000 rpm or 30 K etc.) and use of water for coolant and lavage.
  • These atomized micro-droplets can drift a range of 1-2 meters around dental chair.
  • These particles can also be inhaled by the dental professional, staff and other patients.

Reduce the danger of particle/droplet spread!

  • Aerosols are created during oral treatment.
  • Aerosols suspended in the air for an extended time until they settle on surfaces, clothing and equipment or are inhaled into the human
    respiratory tract.
  • Inhaled aerosolized virus and bacteria have
    strong penetrating power and are considered to be the most potentially dangerous particles for transmitting diseases in the lungs.

 

Vector Vortex Extra Oral External Evacuation Unit 110v/60hz

During treatment, doctors and staff using ultrasonic scalers, 3- way syringe, high and low speed handpieces – generate a large amount of water and mist which combined with bacteria such as saliva, blood and other tissue in the patient’s mouth, producing aerosols. The extra-oral suction of the Vector Vortex removes these aerosols to prevent cross-infection between the doctors and the patients. Providing a clear, dry and clean envioronment.

I Have An HVE: Is it Good Enough?

Intra-oral suction can not significantly reduce droplet dispersion! (particulate matter greater than 0.5)

Vector Vortex Extra Oral External Evacuation Unit 110v/60hz

Dispersion rate=Droplets which are not caught/ Total tracked particles number

  • When using intra-oral suction only, 50% ~ 60% of droplets are flying into the air
  • Using intra-oral and extra-oral suction at the same time, the Vector Vortex captures close to 95% of droplet particles.

Vector Vortex Extra Oral External Evacuation Unit 110v/60hz

Capture rate=Total absorbed particles number /Total tracked particles number

In terms of the “capture rate” of droplet particles. The capture rate of the intra-oral and extra-oral suction combination is 40%~70% higher than that of using intra-oral suction only.

Vector Vortex Extra Oral External Evacuation Unit 110v/60hz

How it works

Suction

With strong suction vacuum pressure and high air suction flow rate, the aerosol droplets between the doctor and staff and the patients is sucked into the machine through the adjustable positioning arm, and discharged after thorough purification.

Disinfection

The aerosol entering the machine is filtered through HEPA filter and then sterilized by ultraviolet rays. The air is then discharged after a high charged plasma sterilization and purification.

4 stages of disinfection ensure clean air!

Vector Vortex Extra Oral External Evacuation Unit 110v/60hz

The built-in high-power blower produces 3M/s wind speed creating a negative air space around the oral cavity, removing dental aerosols and droplets. 4 stage disinfection cleans the air from over 99.97% of vapor, dust, bacteria and viruses. First stage primary filter removes large particles and dust. UV filter exposes viruses and bacteria to UV light breaking down the cellular structure. Plasma generator produces +/- ions charging the particles to make the final stage HEPA filter more effective. Final stage HEPA filter captures the remaining vapor, dust bacteria and viruses.

Advantages and Features

  • Strong suction pump, large flow, high vacuum, long performance life.
  • Excellent heat dissipation performance, can work continuously for more than 4 hours.
  • Negative pressure could be regulated according to the clinical need by stepless adjusting knob.
  • Ergonomic design does not get in you way while still providing effective removal of droplets.
  • Low noise, noise level hardly increases when work with ultrasonic scaler, handpiece etc
Details

Install the free arm and connect the power.

Operation procedure

  1. Move the machine to appropriate location engage the brake at the bottom of wheel.
  2. Plug in the power cord and switch on the power.
  3. Pull the free arm to an appropriate position, adjust the pressure/flow with the knob on the control panel.
  4. After use, turn off the power switch, pull back the free arm.
Specifications
  • Voltage:AC110V 60Hz Power:1200VA
  • Noise:≤65 dB
  • Pumping rate:≥3m3/Min
  • Max Vaccum:-20kpa
  • Amount of negative ions:≥100 million/m3
  • Amount of positive ions:≥80 million/m3
  • HEPA Grade:H13 ≥99.97 0.3μm
  • Dimension:320*320*840mm
  • Net weight:36kg
  • Accessories:
    • HEPA Filter (VV-101)
    • Filter A (VV-102)
    • Filter B (VV-103)
    • UV Lamp (VV-108)
    • Halo Shield (VV-105) Replacement Motor (VV-118)